Last revised 12/07/04
Table of Contents
1. Definitions
and Scope
2. Standards of Practice
2.1. Roof
2.2. Exterior
2.3. Basement, Foundation,
Crawlspace & Structure
2.4. Heating
2.5. Cooling
2.6. Plumbing
2.7. Electrical
2.8. Fireplace
2.9. Attic & Insulation
2.10. Doors, Windows &
Interior
3. Limitations, Exceptions
& Exclusions
4. Glossary of Terms
1. Definitions
and Scope [return to
top]
1.1. A Home inspection is a non-invasive
visual examination of a residential dwelling,
performed for a fee, which is designed to
identify observed material defects within
specific components of said dwelling. Components
may include any combination of mechanical,
structural, electrical, plumbing, or other
essential systems or portions of the home,
as identified and agreed to by the Client
and Inspector, prior to or during the inspection
process.
I. A home inspection is intended to assist
in evaluation of the overall condition of
the dwelling. The inspection is based on
observation of the visible and apparent
condition of the structure and its components
on the date of the inspection and not the
determination of future conditions.
II. A home inspection will not reveal every
problem that exists or ever could exist,
but only those material defects observed
on the day of the inspection.
1.2. A Material defect is a problem with
a residential real property or any portion
of it that would have a significant adverse
impact on the value of the property or that
involves an unreasonable risk to people on
the property. The fact that a structural element,
system or subsystem is near, at or beyond
the end of the normal useful life of such
a structural element, system or subsystem
is not by itself a material defect.
1.3. An Inspection report shall describe
and identify in written format the inspected
systems, structures, and components of the
dwelling and shall identify material defects
observed. Inspection reports may contain recommendations
regarding conditions reported or recommendations
for correction, monitoring or further evaluation
by professionals.
2. Standards
of Practice [return to top]
2.1. Roof
[return to top]
I. The inspector shall inspect from ground
level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney
and other roof penetrations.
E. The general structure of the roof from
the readily accessible panels, doors or
stairs.
II. The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter
drainage pipes.
D. Remove snow, ice, debris or other conditions
that prohibit the observation of the roof
surfaces.
E. Inspect antennae, lightning arresters,
or similar attachments.
2.2. Exterior
[return to top]
I. The inspector shall inspect:
A. The flashing and trim.
B. All exterior doors, decks, stoops,
steps, stairs, porches, railings, eaves,
soffits, fascias, grading, and walkways.
C. And report as in need of repair any
spacings between intermediate balusters,
spindles, or rails for steps, stairways,
balconies, and railings that permit the
passage of an object greater than four
inches in diameter.
D. The vegetation, surface drainage and
retaining walls when these are likely
to adversely affect the building.
E. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm
windows, shutters, awnings, fences, outbuildings,
or exterior accent lighting.
B. Inspect items, including window and
door flashings, which are not visible
or readily accessible from the ground.
C. Inspect geological, geotechnical, or
hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization
measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal
window seals or damaged glass.
2.3. Basement,
Foundation & Crawlspace [return
to top]
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or indications
of active water penetration by probing
a representative sampling of structural
components where deterioration is believed
to be present or where clear indications
of deterioration are present.
F. And report any general indications
of foundation movement that are observed,
such as but not limited to sheetrock cracks,
brick cracks, out-of-square door frames
or floor slopes.
II. The inspector is not required to:
A. Enter any crawlspaces that are not
readily accessible or where entry could
cause damage or pose a hazard to the inspector
in his or her opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible
floats.
D. Identify size, spacing, span, location
or adequacy of foundation bolting, bracing,
joists or support systems.
E. Provide any engineering or architectural
service.
F. Report on the adequacy of any structural
system or component.
2.4. Heating
[return to top]
I. The inspector shall inspect:
A. The heating system and describe the
energy source and heating method using
normal operating controls.
B. And report as in need of repair electric
furnaces which do not operate.
C. And report if inspector deemed the
furnace inaccessible.
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues
or chimneys, fire chambers, the heat exchanger,
the humidifier or dehumidifier, the electronic
air filter, solar heating systems or fuel
tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature,
flow, balance, distribution, size, capacity,
BTU, or supply adequacy of the heating
system.
D. Light pilot flames.
E. Activate heating, heat pump systems,
or other heating systems when ambient
temperatures or other circumstances are
not conducive to safe operation or may
damage the equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
2.5. Cooling
[return to top]
I. The inspector shall inspect:
A. The central cooling equipment using
normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature,
flow, balance, distribution, size, capacity,
BTU, or supply adequacy of the cooling
system.
B. Inspect window units, through-wall
units, or electronic air filters.
C. Operate equipment or systems if exterior
temperature is below 60 degrees Fahrenheit
or when other circumstances are not conducive
to safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration,
heat anticipation or automatic setbacks
or clocks.
E. Examine electrical current, coolant
fluids or gasses, or coolant leakage.
2.6. Plumbing
[return to top]
I. The inspector shall:
A. Inspect the main water shut off valve.
B. Inspect the water heating equipment,
including combustion air, venting, connections,
energy sources, seismic bracing, and verify
the presence or absence of temperature-pressure
relief valves and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including
all fixtures and faucets.
F. Inspect the drain, waste and vent systems,
including all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps testing
sumps with accessible floats.
I. Inspect and describe the water supply,
drain, waste and main fuel shut-off valves,
as well as the location of the water main
and main fuel shut-off valves.
J. Inspect and determine if the water
supply is public or private.
K. Inspect and report as in need of repair
deficiencies in the water supply by viewing
the functional flow in two fixtures operated
simultaneously.
L. Inspect and report as in need of repair
deficiencies in installation and identification
of hot and cold faucets.
M. Inspect and report as in need of repair
mechanical drain-stops that are missing
or do not operate if installed in sinks,
lavatories and tubs.
N. Inspect and report as in need of repair
commodes that have cracks in the ceramic
material, are improperly mounted on the
floor, leak, or have tank components which
do not operate.
II. The inspector is not required to:
A. Light pilot flames.
B. Determine the size, temperature, age,
life expectancy or adequacy of the water
heater.
C. Inspect interiors of flues or chimneys,
water softening or filtering systems,
well pumps or tanks, safety or shut-of
valves, floor drains or sprinkler systems.
D. Determine the exact flow rate, volume,
pressure, temperature, or adequacy of
the water supply.
E. Determine the water quality or potability
or the reliability of the water supply
or source.
F. Open closed plumbing access panels.
G. Inspect clothes washing machine connections.
H. Operate any main, branch or fixture
valve except fixture faucets and hose
faucets attached to the building.
I. Test shower pans, tub and shower surrounds
or enclosures for leakage.
J. Evaluate the compliance with local
or state conservation or energy standards,
or the proper design or sizing of any
water, waste or venting components, fixtures
or piping.
K. Determine the effectiveness of anti-siphon,
back-flow prevention or drain-stop devices.
L. Determine whether there are sufficient
clean-outs for effective cleaning of drains.
M. Evaluate gas, liquid propane or oil
storage tanks.
N. Excavate or otherwise uncover the private
sewage system or its components to determine
size, adequacy or efficiency.
O. Inspect water treatment systems or
water filters.
P. Inspect pressure pumps or bladder tanks.
Q. Evaluate time to obtain hot water at
fixtures, or perform testing of any kind
to water heater elements.
R. Evaluate or determine the adequacy
of combustion air.
S. Test, operate, open or close Watts
210 valves and/or TPR valves.
T. Examine ancillary systems or components,
such as, but not limited to, those relating
to solar water heating, hot water circulation.
2.7. Electrical
[return to top]
I. The inspector shall inspect:
A. The service line.
B. The meter box.
C. The main disconnect.
D. And determine the service amperage.
E. Panels, breakers and fuses.
F. The grounding.
G. The bonding.
H. A representative sampling of switches,
receptacles, light fixtures, and test
all GFCI receptacles and GFCI circuit
breakers observed and deemed to be GFCI's
during the inspection.
I. And report the presence of solid conductor
aluminum branch circuit wiring if readily
visible.
J. And report on any GFCI-tested receptacles
in which power is not present, polarity
is incorrect, the receptacle is not grounded,
is not secured to the wall, the cover
is not in place, the ground fault circuit
interrupter devices are not properly installed
or do not operate properly, or evidence
of arcing or excessive heat is present.
K. The service entrance conductors and
the condition of their sheathing.
L. The ground fault circuit interrupters
with a GFCI tester.
M. And describe the amperage rating of
the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report
as in need of repair deficiencies in the
integrity of the insulation, drip loop,
or separation of conductors at weatherheads
and clearances.
II. The inspector is not required to:
A. Insert any tool, probe or device into
the main or sub-panels.
B. Operate electrical systems that are
shut down.
C. Remove panel covers or dead front covers
if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or
voltage of the main service if not visibly
labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems or
branch circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical
de-icing tapes, swimming pool wiring or
any time-controlled devices.
L. Verify the continuity of the connected
service ground.
M. Inspect private or emergency electrical
supply sources, including but not limited
to generators, windmills, photovoltaic
solar collectors, or battery or electrical
storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct drop voltage calculations.
P. Determine the accuracy of breaker labeling.
2.8. Fireplace
[return to top]
I. The inspector shall inspect:
A. The fireplace, and open and close
the damper door if readily accessible
and operable.
B. Hearth extensions and other permanently
installed components.
C. And report as in need of repair deficiencies
in the lintel, hearth and material surrounding
the fireplace, including clearance from
combustible materials
II. The inspector is not required to:
A. Inspect the vent system.
B. Inspect the interior of the chimney
or flue, fire doors or screens, seals
or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such
installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion make up devices.
I. Inspect heat distribution assists whether
gravity controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or
firebox contents.
M. Determine adequacy of draft, perform
a smoke test or dismantle or remove any
component.
2.9. Attic, Ventilation
& Insulation [return
to top]
I. The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or
lack of insulation.
II. The inspector is not required to:
A. Enter the attic or unfinished spaces
that are not readily accessible or where
entry could cause damage or pose a safety
hazard to the inspector in his or her
opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the surface
finish or weather seal on or around access
panels and covers.
E. Identify the composition or the exact
R-value of insulation material.
F. Activate thermostatically operated
fans.
G. Determine the types of materials used
in insulation/wrapping of pipes, ducts,
jackets, boilers, and wiring.
2.10. Doors,
Windows & Interior [return
to top]
I. The inspector shall:
A. Open and close a representative number
of doors and windows.
B. Inspect the walls, ceilings, steps,
stairways, and railings.
C. Inspect garage doors and garage door
openers by operating first by remote (if
available) and then by the installed automatic
door control.
D. And report as in need of repair any
installed electronic sensors that are
not operable or not installed at proper
heights above the garage door.
E. And report as in need of repair any
door locks or side ropes that have not
been removed or disabled when garage door
opener is in use.
F. And report as in need of repair any
windows that are obviously fogged or display
other evidence of broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments
or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in locations
subject to human impact.
D. Inspect security components.
E. Evaluate the fastening of countertops,
cabinets, sink tops and fixtures, or firewall
compromises.
F. Move furniture, stored items, or any
coverings like carpets or rugs in order
to inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed
in the garage except as otherwise noted.
J. Verify or certify safe operation of
any auto reverse or related safety function
of a garage door.
K. Operate or evaluate security bar release
and opening mechanisms, whether interior
or exterior, including compliance with
local, state, or federal standards.
L. Operate any system, appliance or component
that requires the use of special keys,
codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven
cycles or signal lights.
N. Determine leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny,
kiln, toaster, ice-maker, coffee-maker,
can-opener, bread-warmer, blender, instant
hot water dispenser, or other small, ancillary
devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground,
movable, freestanding, or otherwise non-permanently
installed pool/spa or self-contained equipment.
U. Come into contact with any pool or
spa water in order to determine the system
structure or components.
V. Determine the adequacy of spa jet water
force or bubble effect.
W. Determine the structural integrity
or leakage of a pool or spa.
3. Limitations,
Exceptions & Exclusions [return
to top]
3.1. Limitations: [return
to top]
I. An inspection is not technically exhaustive.
II. An inspection will not identify concealed
or latent defects.
III. An inspection will not deal with aesthetic
concerns or what could be deemed matters
of taste, cosmetic, etc.
IV. An inspection will not determine the
suitability of the property for any use.
V. An inspection does not determine the
market value of the property or its marketability.
VI. An inspection does not determine the
advisability or inadvisability of the purchase
of the inspected property.
VII. An inspection does not determine the
life expectancy of the property or any components
or systems therein.
VIII. An inspection does not include items
not permanently installed.
IX. These Standards of Practice apply only
to homes with four or fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments.
B. The condition of any component or system
that is not readily accessible.
C. The service life expectancy of any
component or system.
D. The size, capacity, BTU, performance,
or efficiency of any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or
replacement of any system or component.
G. Future conditions.
H. The compliance with codes or regulations.
I. The presence of evidence of rodents,
animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials
including, but not limited to, the presence
of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance
with manufacturer installation or any
information included in the consumer protection
bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of how much it will cost
to run any given system.
II. The inspectors are not required to
operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical
systems such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with
the use of normal operating controls.
E. Any shut off valve.
F. Any electrical disconnect or over current
protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar
equipment.
III. The inspectors are not required to:
A. Move any personal items or other obstructions,
such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any system
or component.
C. Enter or access any area which may,
in the opinion of the inspector, to be
unsafe or risk personal safety.
D. Enter crawlspaces or other areas that
are unsafe or not readily accessible.
E. Inspect underground items such as,
but not limited to, underground storage
tanks or other indications of their presence,
whether abandoned or actively used.
F. Do anything which, in the inspector's
opinion, is likely to be unsafe or dangerous
to the inspector or others or damage property,
such as, but not limited to, walking on
roof surfaces, climbing ladders, entering
attic spaces or negotiating with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas in
multi-unit housing.
I. Inspect intercoms, speaker systems,
radio-controlled, security devices or
lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional
service other than home inspection.
M. Research the history of the property,
report on its potential for alteration,
modification, extendibility, or its suitability
for a specific or proposed use for occupancy.
N. Determine the age of construction or
installation of any system structure,
or component of a building, or differentiate
between original construction or subsequent
additions, improvements, renovations or
replacements thereto.
O. Determine the insurability of a property.
4. Glossary
of Terms [return to top]
4.1. Accessible: Can be approached or entered
by the inspector safely, without difficulty,
fear or danger.
4.2. Activate: To turn on, supply power,
or enable systems, equipment, or devices to
become active by normal operating controls.
Examples include turning on the gas or water
supply valves to the fixtures and appliances
and activating electrical breakers or fuses.
4.3. Adversely Affect: Constitute, or potentially
constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices, installed
or free-standing, including but not limited
to: Carbon monoxide detectors, flue gas and
other spillage detectors, security equipment,
ejector pumps and smoke alarms.
4.5. Appliance: A household device operated
by use of electricity or gas. Not included
in this definition are components covered
under central heating, central cooling or
plumbing.
4.6. Architectural Service: Any practice
involving the art and science of building
design for construction of any structure or
grouping of structures and the use of space
within and surrounding the structures or the
design, design development, preparation of
construction contract documents, and administration
of the construction contract.
4.7. Component: A permanently installed or
attached fixture, element or part of a system.
4.8. Condition: The visible and conspicuous
state of being of an object.
4.9. Crawlspace: The area within the confines
of the foundation and between the ground and
the underside of the lowest floor structural
component.
4.10. Decorative: Ornamental; not required
for the operation of essential systems and
components of a home.
4.11. Describe: Report in writing a system
or component by its type, or other observed
characteristics, to distinguish it from other
components used for the same purpose.
4.12. Determine: To arrive at an opinion
or conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or remove
any component, device or piece that would
not typically be opened, taken apart or removed
by an ordinary occupant.
4.14. Engineering Service: Any professional
service or creative work requiring engineering
education, training, and experience and the
application of special knowledge of the mathematical,
physical and engineering sciences to such
professional service or creative work as consultation,
investigation, evaluation, planning, design
and supervision of construction for the purpose
of assuring compliance with the specifications
and design, in conjunction with structures,
buildings, machines, equipment, works or processes.
4.15. Enter: To go into an area to observe
all visible components.
4.16. Evaluate: To assess the systems, structures
or components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the
structure or wall rests; usually masonry,
concrete, or stone, and generally partially
underground.
4.19. Function: The action for which an item,
component, or system is specially fitted or
used or for which an item, component or system
exists; to be in action or perform a task.
4.20. Functional: Performing, or able to
perform, a function.
4.21. Home Inspection: The process by which
an inspector visually examines the readily
accessible systems and components of a home
and operates those systems and components
utilizing these Standards of Practice as a
guideline.
4.22. Household Appliances: Kitchen and laundry
appliances, room air conditioners, and similar
appliances.
4.23. Inspect: To visually look at readily
accessible systems and components safely,
using normal operating controls and accessing
readily accessible panels and areas.
4.24. Inspected Property: The readily accessible
areas of the buildings, site, items, components,
and systems included in the inspection.
4.25. Inspector: One who performs a real
estate inspection.
4.26. Installed: Attached or connected such
that the installed item requires tool for
removal.
4.27. Material Defect: Refer to section 1.2.
4.28. Normal Operating Controls: Devices
such as thermostats that would be operated
by ordinary occupants which require no specialized
skill or knowledge.
4.29. Observe: To see through visually directed
attention.
4.30. Operate: To cause systems to function
or turn on with normal operating controls.
4.31. Readily Accessible: An item or component
is readily accessible if, in the judgment
of the inspector, it is capable of being safely
observed without movement of obstacles, detachment
or disengagement of connecting or securing
devices, or other unsafe or difficult procedures
to gain access.
4.32. Recreational Facilities: Spas, saunas,
steam baths, swimming pools, tennis courts,
playground equipment, and other exercise,
entertainment or athletic facilities.
4.33. Report: A written communication (possibly
including digital images) of any material
defects seen during the inspection.
4.34. Representative Number: A sufficient
number to serve as a typical or characteristic
example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated
glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged, inactive,
not in service, not operational, etc.
4.37. Structural Component: A component which
supports non-variable forces or weights (dead
loads) and variable forces or weights (live
loads).
4.38. System: An assembly of various components
to function as a whole.
4.39. Technically Exhaustive: A comprehensive
and detailed examination beyond the scope
of a real estate home inspection which would
involve or include, but would not be limited
to: dismantling, specialized knowledge or
training, special equipment, measurements,
calculations, testing, research, analysis
or other means.
4.40. Unsafe: A condition in a readily accessible,
installed system or component which is judged
to be a significant risk of personal injury
during normal, day-to-day use. The risk may
be due to damage, deterioration, improper
installation or a change in accepted residential
construction standards.
4.41. Verify: To confirm or substantiate. |